An Example in Steel Casting    Hinge/Bearing Assembly for Log Forwarder

Option B -- One Center Sprue and OD Gating

wpe2.jpg (17410 bytes)

In Option B, the gating system consists of one center sprue for both bearing plates with runners and gates feeding metal into the outer diameter on two sides of each ring.

This gating system design has an unnecessarily long metal flow path which could --

  • Produce non-uniform and incomplete filling of the mold.

  • Introduce turbulence and oxidation in the metal flow.

Option B is not the best gating system design
Go Back to the Options Page